Weldex - DI (Double Insulated)

RR Kabel

Application

Double insulated cable, for welding machines provides higher current carrying capacity. Used to conduct secondary voltage in secondary
side connection to MMA welding power sources.

Technical Data

Voltage Rating : 450V a.c.r.m.s.
Test Voltage : 3000V
Temperature Range : -30°C to +70°C
Minimum Bending Radius : 5 x cable diameter

Cable Construction

Super fine strands of annealed bare copper as per EN 60228, Cl. 6
Elastomeric PVC composite covering.
* Also available with TPE composite covering 105°C

Properties

The heavy duty welding cable is resistant to flame, oil, abrasions, tar and grease.
Suitable for use in open air, in dry as well as damp interiors.
The high degree of flexibility does not form knots on the cable which could lead to internal break of conductors.

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of 'y') for the insulation material required:
0 - TPE, 1 - Elastomeric PVC

Part Number Nominal Cross-Sectional Area (Sq. mm) Max. Strand Diameter (mm) Max. DC Conductor Resistance (Ω/km) Total Radial Thickness of Covering (mm) Maximum Cable Diameter (mm) Approx. Weight (kg/km)
1207y0100010 10 0.30 1.91 3.2 10.0 180
1207y0100016 16 0.30 1.21 3.2 11.5 250
1207y0100025 25 0.30 0.78 3.2 13.0 350
1207y0100035 35 0.30 0.554 3.2 14.5 460
1207y0100050 50 0.30 0.386 3.5 17.0 650
1207y0100070 70 0.30 0.272 3.8 19.0 880
1207y0100095 95 0.30 0.206 4.2 21.5 1170
1207y0100120 120 0.30 0.161 4.5 24.0 1430
1207y0100150 150 0.30 0.129 4.8 26.0 1720