LOADING...

MYANMAR
2:46 AM

Submersible Flat Cable PVC/PVC

Submersible Flat Cable PVC/PVC

Application

The sheath is specially made out to resist tough and difficult outdoor conditions & excellent resistant to water

The PVC insulated and sheathed 3 core flat cables are mainly used in pump connections. They are also used in many industrial applications.
The sheath is specially made out to resist tough and difficult outdoor conditions & excellent resistant to water

Technical Data

Approvals : IS 694 marked, FIA/TAC
Conductor : Electrolytic grade annealed copper
Core Colour : Red, yellow (centre core), blue
Sheath Colour : Black

Voltage Grade : Upto and including 1100V

Packing : Standard packing of 100 mtr. in coils. Longer length available on request.

Variants Available

<

Product Type

Speci?cations

PVC 70°C

IS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type A insulation & ST-1 sheath.

HR 85°C

IS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type C insulation & ST-2 sheath.

 

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of 'y') for the cable type 1 – PVC 70°C, 3 - PVC HR 85°C.

 

Part Number

Conductor construction

Conductor resistance at 20 °C (Ω/km) Max.

 

Nom. Insulation thickness (mm)

Nominal Sheath Thickness  (mm)

Approx. overall dimensions (W X H) (mm) +/- 0.5 mm

Current carrying capacity (Ampere)

Cross sectional area (Sq. mm)

No./Max. dia of strands (mm)

0118110102y1

0.5

16/0.2

39.0

0.6

0.9

9.60 X 4.90

4

0118110202y1

0.75

24/0.2

26.0

0.6

0.9

10.5 X 5.20

7

0118110302y1

1

32/0.2

19.5

0.6

0.9

11.0 X 5.40

12

0118110402y1

1.5*

22/0.3

12.1

0.6

0.9

12.0 X 5.6

18

0118110502y1

2.5*

36/0.3

7.41

0.7

1.0

13.0 X 6.2

24

0118110602y1

4

56/0.30

4.95

0.8

1.0

15.3 X 7.1

28

0118110702y1

6

84/0.30

3.30

0.8

1.1

19.2 X 8.4

36

0118110802y1

10

140/0.30

1.91

1.0

1.4

24.2 X 10.4

48

0118110902y1

16

126/0.40

1.21

1.0

1.4

29.0 X 12.4

64

0118111002y1

25

196/0.40

0.78

1.2

2.0

36.5 X 15.7

80

0118111102y1

35

276/0.40

0.554

1.2

2.0

40.5 X 17.2

100

0118111202y1

50

396/0.40

0.386

1.4

2.2

46.5 X 19.3

130

0118111302y1

70

360/0.50

0.272

1.4

2.2

52.0 X 21.0

192

0118111402y1

95

480/0.50

0.206

1.6

2.4

61.0 X 24.5

230

*Conductor configuration offered for 1.5 Sq mm-22/0.3 mm, 2.5 Sq mm - 36/0.3 mm (max.), class 2 as per IS 8130

Current rating conversion factor for deviating ambient temperature

Multiply the current carrying capacity of the cable by the factors given below for various ambient temperature.

Ambient Temperature (°C)

 

Derating Factor

 

25

1.25

30

1.16

35

1.09

40

1.00

45

0.90

50

0.81

55

0.74

60

0.68

GET IN TOUCH