Application
These are thin walled cables ideal for use in automotives where its reduced insulation thickness and higher temperature withstanding
properties serves its application in complex wiring harnesses.
Standard
In accordance with ISO 6722
Voltage Rating
60 V D.C.; 25 V A.C. (Suitable for 12 Volts and 24 Volts systems)
Temperature Range (3000 Hrs)
-40°C to +105°C
Cable Construction
Soft annealed electrolytic copper Cu-ETP according to DIN EN 13602.
Conductor construction according to ISO 6722 PVC insulation, class B to ISO 6722
Properties
The lead free, PVC polymer, offers excellent resistance to petrol, chemicals, and abrasion, and in addition is suitable for both low and
high temperature applications. Flame retardant to EN 60332-1-2
Packing
Available in 100 mtrs. Longer length available in spools or wooden drums.
Cable Design Parameters
Nom. Cross-Section (mm²)
|
No. of Strands
|
Max. Strand Diameter (mm)
|
Max. Conductor Diameter (mm)
|
Max. DC Conductor Resistance at 20oC (Ω/km)
|
Min. Insulation Thickness (mm)
|
Max. Overall Diameter (mm)
|
Plain Copper
|
Tinned Copper
|
0.35
|
12
|
0.21
|
0.9
|
54.4
|
55.5
|
0.2
|
1.4
|
0.5
|
16
|
0.21
|
1.0
|
37.5
|
38.2
|
0.22
|
1.6
|
0.75
|
24
|
0.21
|
1.2
|
24.7
|
25.4
|
0.24
|
1.9
|
1
|
32
|
0.21
|
1.35
|
18.5
|
19.1
|
0.24
|
2.1
|
1.25
|
16
|
0.33
|
1.5
|
14.9
|
15.9
|
0.24
|
2.3
|
1.5
|
30
|
0.26
|
1.7
|
12.7
|
13
|
0.24
|
2.4
|
2
|
30
|
0.31
|
2.0
|
9.42
|
9.69
|
0.28
|
2.8
|
2.5
|
50
|
0.26
|
2.2
|
7.6
|
7.82
|
0.28
|
3.0
|
3
|
45
|
0.31
|
2.4
|
6.15
|
6.36
|
0.28
|
3.4
|
4
|
56
|
0.31
|
2.75
|
4.71
|
4.85
|
0.32
|
3.7
|
5
|
65
|
0.33
|
3.1
|
3.94
|
4.02
|
0.32
|
4.2
|
6
|
84
|
0.31
|
3.3
|
3.14
|
3.23
|
0.32
|
4.3
|
8
|
50
|
0.46
|
3.8
|
2.38
|
2.52
|
0.32
|
5.0
|
10
|
80
|
0.41
|
4.5
|
1.82
|
1.85
|
0.48
|
6.0
|
12
|
96
|
0.41
|
5.2
|
1.52
|
1.6
|
0.48
|
6.5
|
16
|
18
|
0.41
|
5.5
|
1.16
|
1.18
|
0.52
|
7.2
|
20
|
152
|
0.41
|
5.8
|
0.955
|
0.999
|
0.52
|
7.8
|
25
|
196
|
0.41
|
7.8
|
0.743
|
0.757
|
0.52
|
8.7
|